Socomec Masterys IP+ Rail OLI UPS

Socomec Masterys IP+ Rail OLI UPS


Key Benefits

• Full Range 20-120 kVA
• IP Protection Degree: IP31 standard
• High Efficiency
• Coated Electronic Boards
• Full Galvanic Isolation
• External Manual Bypass
• (Low Smoke Zero Halogen option)

 

Socomec’s IP+ Rail (OLI) offers increased energy availability:  the system can take inputs from both a 25 kV overhead line as well as a 400V AC mains supply.

 

 

As a result, this solution potentially avoids the need for a diesel generator and its associated maintenance, fuel storage and refuelling costs.

 

The innovative rectifier stage converts the input voltage into a DC voltage that will charge both the UPS battery and supply the input stage of the inverter.

 

In normal mode*, the upstream voltage of the rectifier corresponds to the transformed single phase voltage of the overhead line. The transformer and voltage stabiliser eliminates voltage sags and surges related to current draw of locomotives. When this voltage is not present or is no longer with intolerance, it is the 3 phase DNO supply which is sent directly to the UPS rectifier.

 

The inverter converts the DC voltage, provided either from the rectifier output or from the battery in a perfect sinusoidal voltage distributed to the critical loads. The UPS is also equipped with an automatic bypass which allows a no-break transfer of the load directly onto the mains supply in case of overload or faults.

 

An external manual bypass completes the solution to allow for maintenance of the UPS.

Product Snapshot
Input
Rated voltage:
230V 1ph+n/2 ph coming from overhead line 400V 3ph+n coming from mains or generator
Voltage tolerances:
± 20%(3) (up to -40% @ 50% of rated power)
Rated frequency:
50 / 60 Hz
Frequency tolerance:
± 10 Hz
Power factor/THDI:
0.99 / < 3%
Output
Rated voltage 3/1UPS:
1ph+n/2ph 230(220/240 configurable ) (3)
Rated voltage 3/3UPS:
3ph + N: 400 V (380/415 V configurable) (3)
Voltage tolerance static load:
± 1%
Rated frequency:
50 / 60 Hz
Frequency tolerance:
± 2% (configurable from 1% to 8% with generating set)
Total output voltage distortion - linear load:
< 1 %
Total output voltage distortion - non-linear load:
< 5 %
Overload:
125% for 10 minutes, 150% for 1 minute (1)
Crest factor:
3:1 (complying with IEC 62040-3)
Power factor without derating:
From 0.6 lagging up to 0.9 leading
Bypass
Rated voltage 3/1UPS:
1ph + N/ 2ph: 230 V
Rated voltage 3/3UPS:
3ph + N: 400 V
Voltage tolerance:
± 15% (configurable from 10% to 20% with generating set)
Rated frequency:
50/60 Hz
Frequency tolerance:
± 2% (configurable from 1% to 8% with generating set)
Environment
Operating ambient temperature:
from 0 °C up to +40 °C (from 15 °C to 25 °C for maximum battery life)
Relative humidity:
0% - 95% without condensation
Maximum altitude:
1000 m without declassing (max. 3000 m)
UPS single cabinet
Degree of protection:
IP31 and IP52 as option (according to IEC 60529) Coated electronic boards
Colours:
RAL 7012
Standards
Safety:
EN 62040-1 (TÜV SÜD certified), EN 60950-1 LOW SMOKE ZERO HALOGEN CABLES & CABINET COATING
EMC:
EN 62040-2 (2nd Edition) G-222 EN 50121
Performance:
EN 62040-3 [VFI-SS-111]
Product declaration:
CE
Model
Width (mm)
Depth (mm)
Weight (kg)
(3/1)
600
800
1400
1000
835
1400
(3/1)
600
800
1400
1000
835
1400
700
835
1930
Changeover cabinet
800
835
1930
1000
835
1930
1600
835
1930

Standard electrical features

• Dual input mains.
• Internal maintanance bypass.
• Backfeed protection: detection circuit.
• EBS (Expert Battery System) for battery management.


Standard communication features

• Multilanguage graphic display.
• Dry-contact interface.
• MODBUS/JBUS RTU.
• Embedded LAN interface (web pages, email).
• 2 slots for communication options.


Remote maintenance

• LINK-UPS: maintenance software for continuous 24/7 monitoring of the SOCOMEC UPS.

No files available

Electrical options

• Long-life batteries.
• External battery cabinet (degree of protection up to IP32).
• External temperature sensor.
• Additional battery chargers.
• Additional transformer.
• Parallel kit.
• Cold start.
• ACS synchronization system.
• Neutral creation kit for mains without neutral.
• Tropicalization and anti-corrosion protection for electrical boards.

 

Communication options

• Remote mimic panel.
• Profibus.
• MODBUS TCP.
• NET VISION: professional WEB/SNMP interface for UPS monitoring and shutdown management of several operating systems.

 

Do you have a similar problem? We can help.
Call 1300 191 365 or email support@fusionps.com.au

Think these products may suit an issue you have?
For sales questions and information

Get in touch a member of our helpful sales team:

Call 1300 911 365 (Local call)
For international customers +61 3 8677 5600
Monday – Thursday / 8am – 7pm EST
Friday 8am – 6pm EST
Email
sales@fusionps.com.au

Write a review

security


No Reviews | Be the first person to write a review on this product!