Socomec Green Power 2.0 (10-120 kVA/kW) UPS

Socomec Green Power 2.0 (10-120 kVA/kW) UPS


The solution for

• Data centres
• Telecommunications
• Service sector
• IT Networks/ Infrastructures

 

Advantages

 

Energy saving + Full rated power = TCO

 

Energy Saving: high efficiency without compromise

• Offers the highest efficiency in the market using VFI – Double Conversion Mode, the only UPS working-mode that assures total load protection against all mains quality problems.
• Ultra high efficiency output independently tested and verified by an international certification organization in a wide range of load and voltage operating conditions, to have the value in the real site conditions.
• Ultra high efficiency in VFI mode is provided by an innovative topology (3-Level technology) that has been developed for all the Green Power UPS ranges.

 

Full-rated power: kW=kVA

• No power downgrading when supplying the latest generation of servers in typical data centre conditions.
• Full power UPS design up to 35 °C, with 25% more power compared to UPS with PF=0.8 and 11% more power compared to UPS with PF=0.9.
• Suitable also for leading power factor loads down to 0.9 without derating.

 

Significant cost savings (TCO)

• Maximum energy saving thanks to 96% output efficiency: 50% saving on energy losses compared to legacy UPS gives significant savings in energy bill.
• UPS “self-paying” with energy saving.
• Energy Saver mode for global efficiency improvement on parallel systems.
kW=kVA means maximum power available with the same size of UPS, and therefore less €/kW
• With its “clean rectifier“, Green Power UPS significantly optimize the upstream infrastructure without over rating the supply system (i.e. generator sets, switches, cables, protection devices).
• High efficiency minimizes the amount of battery for an equivalent back-up time.
• Battery configuration can be optimized, thanks to a very wide DC range.
• Extended battery life and performance:
- long life battery,
- very wide input voltage (-40% / +20%) and frequency (45 to 65 Hz) without battery use,
- EBS (Expert Battery System) charging management improves battery service life."

Product Snapshot
Input
Rated voltage:
400 V (3ph + N)
Voltage tolerance:
240 V to 480 V(1)
Rated frequency:
240 V to 480 V(1)
Power factor / THDI:
> 0.99 / < 2.5%
Output
Voltage tolerance:
static load ±1 % dynamic load in accordance with VFI-SS-111
Rated frequency:
50 / 60 Hz
Frequency tolerance:
± 2% (configurable from 1% to 8%)
Total output voltage distortion - linear load:
< 1 %
Rated voltage:
1ph + N: 230 V (can be configured 220/240 V) / 3ph + N: 400 V (can be configured 380/415 V)
Total output voltage distortion - non-linear load:
< 3%
Overload:
125% for 10 minutes, 150% for 1 minute (1)
Crest factor:
3:1
Bypass
Rated voltage:
rated output voltage
rated output voltage
± 15% (configurable with from 10% to 20%)
Rated frequency:
50 / 60 Hz
Frequency tolerance:
± 2%
Efficiency (TÜV SÜD verified)
Online mode @ 50 % of load:
up to 96%
Online mode @ 75 % of load:
up to 96%
Online mode @ 100 % of load:
up to 96%
Eco Mode:
up to 98%
Environment
Environment
from 0 °C up to +35 °C (from 15 °C to 25 °C for maximum battery life)
Relative Humidity:
0% - 95% without condensation
0% - 95% without condensation
1000 m without derating (max. 3000 m)
Mod-System
Safety:
EN 62040-1 (TÜV SÜD certified), EN 60950-1
Performance:
EN62040-3 (VFI-SS-111)
Electromagnetic compatibility (EMC):
EN62040-2
Product declaration:
CE
Dimension and weight - UPS single cabinet
Degree of protection
Colours
Width (mm)
Depth (mm)
Height (mm)
Weight (kg)
IP 20
RAL 7012
444
795
800
190
IP 20
RAL 7012
444
795
800
195
IP 20
RAL 7012
444
795
1000
195
IP 20
RAL 7012
444
795
1000
315
IP 20
RAL 7012
444
795
1400
320
IP 20
RAL 7012
600
800
1400
180
IP 20
RAL 7012
600
800
1400
200
IP 20
RAL 7012
700
800
1930
380
IP 20
RAL 7012
700
800
1930
460

Advanced interface

• Up to 30 languages embedded.
• Colour graphic display.
• Commissioning wizard.

 

Standard electrical features

• Dual input mains.
• Internal maintanance bypass.
• Backfeed protection: detection circuit.
• EBS (Expert Battery System) for battery management.
• External temperature sensor.

 

Electrical options

• External maintanance bypass.
• External battery cabinet.
• Additional battery chargers.
• Galvanic isolation transformer.
• Parallel kit.
• ACS synchronization system.

 

Standard communication features

• MODBUS TCP.
• MODBUS/JBUS RTU.
• Embedded LAN interface (web pages, email).
• 2 slots for communication options.

 

Communication options

• Remote mimic panel.
• Dry-contact interface.
• PROFIBUS
• NET VISION: professional WEB/SNM interface for UPS monitoring and shutdown management of several operating systems.

 

Remote maintenance

• LINK-UPS: maintenance software for continuous 24/7 monitoring of the SOCOMEC.

Please see available files below:

Socomec Green Power 2.0 (10-120 kVA/kW) Brochure

There are no additional options for Socomec Green Power 2.0 (10-120 kVA/kW).
Do you have a similar problem? We can help.
Call 1300 191 365 or email support@fusionps.com.au

Think these products may suit an issue you have?
For sales questions and information

Get in touch a member of our helpful sales team:

Call 1300 911 365 (Local call)
For international customers +61 3 8677 5600
Monday – Thursday / 8am – 7pm EST
Friday 8am – 6pm EST
Email
sales@fusionps.com.au

Write a review

security