Novaris SFM 40 63A Surge Filter

Novaris SFM 40 63A Surge Filter


Novaris SFM surge filters provide excellent and effective MSB and DB protection for critical equipment up to 63A per phase.
 
Product Snapshot
Nominal voltage: 230 V / 50 Hz (110 V / 60 Hz by request only)
Maximum continuous voltage: 275 V / 50 Hz (130 V / 60 Hz by request only)
Protection stages: Metal oxide varistor / LC filter / metal oxide varistor
Voltage protection level @ 3kA (8/20μs): <360 V
Response time: <360 V
Earth leakage current: <1 µA
Maximum voltage drop (% of U0):
<1 %
Alarms: Segment failure and overcurrent / thermal overload, SPDT contact
Alarm isolation to active circuitry: 4 kV
Discharge Current variations: 150 kA / 200 kA / 250 kA
Dimension and weight - UPS single cabinet
Part Number
Phases
Discharge current (8/20µs) (kA)
Width (mm)
Height (mm)
Depth (mm)
SFM1-40-50-275
1
50
310
390
130
SFM1-40-100-275
1
100
310
390
130
SFM3-40-50-275
3
50
426
506
130
SFM3-40-100-275
3
100
426
506
200
SFM1-63-50-275
1
50
310
390
130
SFM1-63-100-275
1
100
310
390
130
SFM3-63-50-275
3
50
426
506
130
SFM3-63-50-275
3
100
426
506
200
  • Compliant - Compliant with the relevant IEC lightning and surge protection standards, in particular IEC 62305 and IEC 61643.
  • All Mode Protection - Novaris models featuring all mode protection provide protection for all combinations of lines (L-N, L-E, N-E) ensuring the maximum level of protection is achieved at all times. They have been designed for installation in any wiring system worldwide.
  • Multiple Stages - Models featuring multistage transient protection deliver greater levels of protection through a staged approach. The primary stage absorbs the majority of the surge energy. The  remaining stages provide accurate clamping and a degree of redundancy.
  • Redundant Segments - Models featuring redundant segments have a parallel redundant arrangement of high energy metal oxide varistors (MOVs), thus promoting long life and exceptional surge handling capacity.
  • Thermal Sensing - Sustained overvoltages can cause components to overheat and degrade. Thermal sensing warns of this condition without disconnecting the protection.
  • Percent Active Display- A digital display confirms the device rating upon switch on, then displays percentage active. The display indicates segment status and thermal overload.
  • LED Indicators - Provided to indicate operating status.
  • Surge Indicator Panel - The Novaris Surge Indicator Panel (SIP) allows remote monitoring of any Novaris product featuring external alarms. Models featuring external alarms have voltage free changeover contacts (SPDT) for remote status indication.
  • All Metal Enclosures - Novaris surge protection products are housed in safe, all metal enclosures. In the event of a prolonged overvoltage they will not catch fire or explode.

Please see available files below:

Novaris SFM 40-63A Brochure

 

Description
Code
Circuit breaker
C
 HRC fusing
H
Metal enclosure IP 55
M
Over / under voltage relay
O
Extended voltage (95-415V)
X
Do you have a similar problem? We can help.
Call 1300 191 365 or email support@fusionps.com.au

Think these products may suit an issue you have?
For sales questions and information

Get in touch a member of our helpful sales team:

Call 1300 911 365 (Local call)
For international customers +61 3 8677 5600
Monday – Thursday / 8am – 7pm EST
Friday 8am – 6pm EST
Email
sales@fusionps.com.au

Write a review

security


No Reviews | Be the first person to write a review on this product!