Novaris SFD 2 - 10A Surge Filter

Novaris SFD 2 - 10A Surge Filter


Novaris SFD surge filters provide the highest level of protection for critical and essential equipment up to 10A per phase.
 
Product Snapshot
Nominal voltage: 230V / 50Hz
Maximum continuous voltage: 275V / 50Hz
Protection stages: Metal oxide varistor / LC filter / metal oxide varistor
Voltage protection level @ 3kA (8/20μs): <700V
Response time: Instantaneous
Earth leakage current: <500µA
Maximum voltage drop (% of U0): <1%
Depth: 78 mm
Model
Part Number
Phases
Maximum discharge current (8/20µs) (kA)
Maximum load current (A)
Alarm isolation to active circuitry
Weight (kg)
SFD1-2-6.5-275
1
6.5
2
-
0.35
SFD1-6-6.5-275
1
6.5
6
-
0.35
SFD3-6-13-275-A
3
13
6
-
1.2
SFD3-6-50-275-A
3
50
6
-
1.2
SFD1-10-13-275
1
13
10
4kV
0.45
SFD1-10-50-275-A
1
50
10
4kV
1.05
SFD3-10-13-275-A
3
13
10
4kV
1.55
SFD3-10-50-275-A
3
50
10
4kV
1.55
  • Compliant - Compliant with the relevant IEC lightning and surge protection standards, in particular IEC 62305 and IEC 61643.
  • All Mode Protection - Novaris models featuring all mode protection provide protection for all combinations of lines (L-N, L-E, N-E) ensuring the maximum level of protection is achieved at all times. They have been designed for installation in any wiring system worldwide.
  • Multiple Stages - Models featuring multistage transient protection deliver greater levels of protection through a staged approach. The primary stage absorbs the majority of the surge energy. The  remaining stages provide accurate clamping and a degree of redundancy.
  • LED Indicators - Provided to indicate operating status.
  • Surge Indicator Panel - The Novaris Surge Indicator Panel (SIP) allows remote monitoring of any Novaris product featuring external alarms. Models featuring external alarms have voltage free changeover contacts (SPDT) for remote status indication.
  • DIN Rail Complaint - Protection devices housed in DIN 43880 compliant enclosures allow for convenient installation on DIN rail fittings commonly used in switchboards worldwide.
  • All Metal Enclosures - Novaris surge protection products are housed in safe, all metal enclosures. In the event of a prolonged overvoltage they will not catch fire or explode.

Please see available files below:

Novaris SFD 2-10A Brochure

 

Part Number
LED indication and external alarm
LED indication only
Voltage variation
SFD1-2-6.5-275
-
L*
30V / 50V / 130V
SFD1-6-6.5-275
-
L*
30V / 50V / 130V
SFD3-6-13-275-A
Standard
L
50V / 130V
SFD3-6-50-275-A
Standard
L
130V
SFD1-10-13-275
Standard
L
50V / 130V
SFD1-10-50-275-A
Standard
L
130V
SFD3-10-13-275-A
Standard
L
50V / 130V
SFD3-10-50-275-A
Standard
L
130V
Do you have a similar problem? We can help.
Call 1300 191 365 or email support@fusionps.com.au

Think these products may suit an issue you have?
For sales questions and information

Get in touch a member of our helpful sales team:

Call 1300 911 365 (Local call)
For international customers +61 3 8677 5600
Monday – Thursday / 8am – 7pm EST
Friday 8am – 6pm EST
Email
sales@fusionps.com.au

Write a review