MFB RFI Shielded Rack

MFB RFI Shielded Rack


This range of purpose built cabinets have been developed to meet the stringent requirements of RFI/EMI Shielding. They provide electromagnetic attenuation better than 80dB to signals between 10KHz and 1GHz.

600mm RFI/EMI Cabinet with Doors

RU
Height
Depth
Suit 1 Door Code
Weight
Suit 2 Door Code
Weight
6
477
450
02290-13
39
02291-13
44
600
02290-14
45
02291-14
50
800
02290-15
54
02291-15
59
12
743
450
02290-16
50
02291-16
56
600
02290-17
65
02291-17
71
800
02290-18
65
02291-18
73
18
1010
450
02290-01
65
02291-01
73
600
02290-05
73
02291-05
81
800
02290-09
84
02291-09
92
27
1410
450
02290-02
86
02291-02
97
600
02290-06
97
02291-06
108
800
02290-10
111
02291-10
122
39
1944
450
02290-03
114
02291-03
129
600
02290-07
128
02291-07
14
800
02290-11
146
02291-11
161
45
2210
450
02290-04
128
02291-04
144
600
02290-08
143
02291-08
159
800
02290-12
163
02291-12
179

800mm Industrial Cabinet Frames

RU
Height
Depth
Suit 1 Door Code
Weight
Suit 2 Door Code
Weight
6
477
450
02292-01
42
02293-01
45
600
02292-07
48
02293-07
51
800
02292-13
57
02293-13
59
12
743
450
02292-02
54
02293-02
58
600
02292-08
69
02293-08
77
800
02292-14
71
02293-14
74
18
1010
450
02292-03
70
02293-03
77
600
02292-09
78
02293-09
77
800
02292-15
89
02293-15
94
27
1410
450
02292-04
93
02293-04
100
600
02292-10
104
02293-10
110
800
02292-16
118
02293-16
123
39
1944
450
02292-05
124
02293-05
134
600
02292-11
138
02293-11
147
800
02292-17
156
02293-17
164
5
2210
450
02292-06
139
02293-06
150
600
02292-12
154
02293-12
164
800
02292-18
174
02293-18
183

No files available

  • Line Entry - is through in-line filters usually fitted with a shortened rear door opton. This must be determined at time of ordering.
  • Fibre Optic Entry - is achieved by passing the fibre optic cables through a filter.
  • Acrylic Viewing Port - can be fitted to the cabinet doors, this port includes a black steel mesh shield, which becomes near invisible when back lit by a video monitor, indicator lamps, etc. However, some down grading of the shielding effectiveness may occur and the port should be made as small as possible to minimise this loss.
  • Gear Trays - can be fitted inside the rear of the cabinet, either full height or partial, finished in either white or international orange baked enamel & fabricated from 3.0mm steel.
  • Plinth - is 90mm high and incorporates levelling feet and bolt down brackets to secure to the floor. Finished in black powdercoat and is available either plain or vented. Refer to page 74 for more details.
  • Eye Bolt - provision is made on all cabinets. However, the eye bolts must be ordered if required. Load capacity of 600kg but spreader bars must be used to meet this rating.
  • Single Line Entry - is achieved by passing a single cable through a wave guide tube which is fitted at the time of manufacture. It is best suited to Fibre Optic cable. Any-current carrying conductors, including Data, penetrating the shield should be filtered. The position must be specified at the time of ordering.
  • Weather Hood - for cabinets used outdoors. This hood provides additional protection from the elements.

Write a review

security


No Reviews | Be the first person to write a review on this product!