ION F-15 UPS

ION F-15 UPS


ION F-15 is the latest Pure Sine Wave Line Interactive UPS supplying clean and reliable network-grade power in tower, rack and tower or convertible form.

With automatic voltage regulation (AVR), ION F-15 it the affordable way to protect switches, servers, networking devices, security and point-of-sale equipment.

PROTECTION FOR:

  • Servers
  • Switches
  • Routers
  • Networking Devices
  • Storage Devices

PERFECT FOR:

  • Office Computer
  • Server Rooms
  • Commercial IT
  • Retail POS
  • IP Telephony
  • Security Applications
  • Short Depth Rack
  • Mount Solutions
Product Snapshot
 
F15-500A
F15-750A
F15-1000A
F15-1500A

Capacity

VA/W:
500/300
750/500
1000/600
1500/870

Input

Voltage:
220/230/240 VAC
Acceptable Voltage range:
0-300VAC
Normal Frequency:
0-300VAC

Output

Voltage:
220/230/240VAC
Regulation (Normal Mode):
(+/-15% Max) of normal voltage
Regulation (Battery Mode):
(+/-10%) / (+/-5%)
Voltage Waveform:
Pure Sine Wave
Frequency:
50Hz

Overload Capacity

Normal Mode:
(110% +8%), fault after 3 minutes:(130% +8%), fault after 10 cycles minimum
Boost/Buck Mode:
(70% +8%/-4%): overload alarming after 25 minutes, fault after 30 minutes
Battery Mode:
110% ±8%, fault after 30 seconds; 120% ±8%, fault after 5 cycles minimum

Connections

Inlet:
IEC C14 (1)
IEC C14 (1)
IEC C14 (1)
IEC C14 (1)
Outlets:
IEC C13 (4)
IEC C13 (4)
IEC C13 (6)
IEC C13 (6)

Transfer Time

Typical:
2-7 ms typical, 10ms max

Transfer Time

Normal Mode:
> 95% (Rated full load, battery full charged)
Boost/Buck Mode:
> 90% (Rated full load, battery full charged)
Battery Mode
> 80% (Rated full load, battery full charged

Back Up Time

50% load Backup Time (Typical):
12 min
8 min
11 min
10 min
100% load Backup Time (Typical)
6 min
4 min
6 min
5 min

Indicator

LED Display:

UPS Status / Load Level / Battery Level / Fault

Audible Alarm

Back up mode:
Sounding every 10 seconds
Battery low:
Sounding every 1 seconds
Overload:
Sounding every 0.5 seconds
Over charge:
Sounding every 1.5 seconds
Over temperature:
Sounding every 2.5 seconds
Over temperature:
Sounding every 2.5 seconds
Battery replace:
Sounding every 3 seconds
Charger fail:
Sounding every 5 seconds
Fault:
Continuous sound
Model
 
Length (mm)
Width (mm)
Height (mm)
Weight (kg)
F15-500A
323
96
234.6
5.6
F15-750A
323
96
234.6
6
F15-1000A
390
96
328
9.8
F15-1500A
390
96
328
10.2

Please see available files below: