APC Smart-UPS RT UPS

APC Smart-UPS RT UPS


Smart-UPS On-Line provides high density, true double-conversion on-line power protection for servers, voice / data networks, medical labs, and light industrial applications.

Product Snapshot
Nominal Input Voltage: 230V
Crest Factor: 3 : 1
Input Frequency: 50/60 Hz +/- 5 Hz (auto sensing)
Waveform Type: Sine wave
Model
Part Number
Output Power Capacity (Watts / VA)
Input Connections
Bypass
SURT1000RMXLI
700 / 1000
IEC-320 C14
Built-in Bypass
SURT1000XLI
700 / 1000
IEC-320 C14
Built-in Bypass
 
SURT2000RMXLI
1400 / 2000
IEC-320 C20 Schuko CEE 7 / EU1-16P British BS1363A
Built-in Bypass
SURT2000XLI
1400 / 2000
IEC-320 C20 Schuko CEE 7 / EU1-16P British BS1363A
Built-in Bypass
 
SURTD3000RMXLI
2100 / 3000
British BS1363A IEC-320 C20 Schuko CEE 7/EU1-16P
Internal Bypass (Automatic and Manual)
SURTD3000XLI
2100 / 3000
British BS1363A IEC-320 C20 Schuko CEE 7/EU1-16P
Internal Bypass (Automatic and Manual)
 
SURTD5000RMXLI
3500 / 5000
Hard Wire 3-wire
Internal Bypass (Automatic and Manual)
SURTD5000XLI
3500 / 5000
Hard Wire 3-wire
Internal Bypass (Automatic and Manual)
 
SURT6000RMXLI
4200 / 6000
Hard Wire 3-wire
Internal Bypass (Automatic and Manual)
SURT6000XLI
4200 / 6000
Hard Wire 3-wire
Internal Bypass (Automatic and Manual)
 
SURT8000RMXLI
6400 / 8000
Hard Wire 3 wire (1PH+N+G) Hard Wire 5-wire (3PH + N + G)
Internal Bypass (Automatic and Manual)
SURT8000XLI
6400 / 8000
Hard Wire 3 wire (1PH+N+G) Hard Wire 5-wire (3PH + N + G)
Internal Bypass (Automatic and Manual)
 
SURT10000RMXLI
8000 / 10
Hard Wire 3 wire (1PH+N+G) Hard Wire 5-wire (3PH + N + G)
Internal Bypass (Automatic and Manual)
SURT10000XLI
8000 / 10
Hard Wire 3 wire (1PH+N+G) Hard Wire 5-wire (3PH + N + G)
Internal Bypass (Automatic and Manual)
  • Battery-protected and surge-only outlets - Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment.

Availability

  • Boost and Trim Automatic Voltage Regulation (AVR) - Gives higher application availability by correcting low and high voltage conditions without using the battery.
  • Intelligent battery management - Maximizes battery performance, life, and reliability through intelligent, precision charging.
  • Power conditioning - Protects connected loads from surges, spikes, lightning, and other power disturbances.
  • Temperature-compensated battery charging - Prolongs battery life by regulating the charge voltage according to battery temperature.
  • Automatic restart of loads after UPS shutdown - Automatically starts up the connected equipment upon the return of utility power.
  • Automatic self-test - Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • Cold-start capable - Provides temporary battery power when the utility power is out.
  • Disconnected battery notification - Warns when a battery is not available to provide backup power. 

Manageability

  • Network manageable - Provides remote management of the UPS over the network.
  • Audible alarms - Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.
  • LED status indicators - Quickly understand unit and power status with visual indicators.
  • Serial Connectivity - Provides management of the UPS via a serial port.
  • USB connectivity - Provides management of the UPS via a USB port (not available on all models).
  • Disconnected battery notification - Warns when a battery is not available to provide backup power.

 Serviceability

  • User-replaceable batteries - Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
  • Hot-swappable batteries - Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
  • Predictive failure notification - Provides early-warning fault analysis ensuring proactive component replacement.
  • Resettable circuit breakers - Enables a quick recovery from overload events. 

Adaptability

  • Adjustable voltage-transfer points - Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
  • Adjustable voltage sensitivity - Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
  • Field-replaceable power distribution panel - Ensures compatibility with equipment that has different plug types. 

 Safety

  • Safety-agency approved - Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Replacement Battery Packs
Replacement Battery Packs for this product are available. Contact Fusion on 1300 911 365 for more information.
Description
Part Number
Batteries
APC Smart-UPS RT 48V RM Battery Pack
SURT48RMXLBP
APC Smart-UPS RT 192V RM Battery Pack
SURT192RMXLBP
APC Smart-UPS RT 192V Battery Pack
SURT192XLBP
Replacement Batteries
APC Replacement Battery Cartridge #31
RBC31
APC Replacement Battery Cartridge #44
RBC44
Service Bypass Panels
APC SERVICE BYPASS PDU, 230V 10AMP W/ (6) IEC C13
SBP1500RMI
APC SERVICE BYPASS PDU, 230V 16AMP Hardwire
SBP3000RMHW
APC SERVICE BYPASS PDU, 230V 16AMP W/ (6) IEC C13 AND (1) C19
SBP3000RMI
APC Service Bypass Panel- 230V; 50A; BBM; IEC320 C20/HW input; IEC-320 Output- (2) C19 (8) C13
SBP5000RMI2U
APC Service Bypass Panel- 200/208/240V; 100A; MBB; Hardwire input/output
SBP16KP
APC Service Bypass Panel- 230V; 100A; MBB; Hardwire input;
IEC-320 output- (8) C13 (2) C19
SBP10KRMI4U
APC Service Bypass Panel- 230V; 100A; MBB; Hardwire input; (3) 30A Hardwire Output
SBP16KRMI4U
Network Management
UPS Network Management Card 2
AP9630
UPS Network Management Card 2 with Environmental Monitoring
AP9631
Do you have a similar problem? We can help.
Call 1300 191 365 or email support@fusionps.com.au

Think these products may suit an issue you have?
For sales questions and information

Get in touch a member of our helpful sales team:

Call 1300 911 365 (Local call)
For international customers +61 3 8677 5600
Monday – Thursday / 8am – 7pm EST
Friday 8am – 6pm EST
Email
sales@fusionps.com.au

Write a review

security


No Reviews | Be the first person to write a review on this product!